Edge Rewrite
// HTMLRewriter · presentation

This page was redesigned at the edge.

Cloudflare fetched the original article and streamed it through HTMLRewriter to apply an entirely new visual system without rebuilding the source page.

Jump to content

Talk:Ferromagnetic material properties

Page contents not supported in other languages.
Add topic
From Wikipedia, the free encyclopedia
Latest comment: 4 years ago by 2601:4A:4201:8520:EC81:D040:13D2:E81B
  • maximum permeability is not used in Philips handbook - it was took from other source;
  • A_min is A_e min in Philips handbook - probably typo error (it is just below A_e) - need verification;
  • µ_i uses 'lim' in Philips handbook - seems to be 'overkill'; also the definition in handbook is physically incorrect, as it does not take into account the B_r - remaining induction when H=0 - the 'lim' is infinite! 'initially demagnetized' added to the handbook definition;
  • saturation induction, resistivity, and mass density - not specified in the handbook in 'SYMBOLS AND DEFINITIONS OF TERMS', but used in material description; the first is not obvious: it is measured for some standard H values, these values are different for different µ;
  • hysteresis constant and d.c. sensitivity constant - seems the explanation in the handbook is unclear and may contain typo error - need other source for their definitions;
  • 'effective' parameters for 'magnetic core parameters' - comparison to a toroid was for the volume only, seems it is correct for all four parameters;

JerzyTarasiuk (talk) 21:09, 21 May 2009 (UTC)Reply

Why doesn't this article get merged with the article on Ferromagnetism? 2601:4A:4201:8520:EC81:D040:13D2:E81B (talk) 00:45, 28 August 2022 (UTC)Reply