Edge Rewrite
// HTMLRewriter · presentation

This page was redesigned at the edge.

Cloudflare fetched the original article and streamed it through HTMLRewriter to apply an entirely new visual system without rebuilding the source page.

Jump to content

Talk:Direct reduction

Page contents not supported in other languages.
Add topic
From Wikipedia, the free encyclopedia
Latest comment: 2 years ago by 2001:569:F82B:5B00:7468:1241:6076:AB25 in topic Re Iron Oxide Reaction Temperatures
WikiProject iconIntertranswiki/OKA
WikiProject iconThis article has been created, improved, or expanded by a translator from the Open Knowledge Association. See the OKA task force page of WikiProject Intertranswiki.WikiProject icon

Carlos Eduardo Wester Pérez (talk) 22:42, 27 September 2023 (UTC)Reply

Re Iron Oxide Reaction Temperatures

[edit]

Hey I don't typically edit Wikipedia but the temperatures given for iron oxide reduction seem way off. According to this article from steel research international in 2019, hematite reduction can occur below 570 °C, magnetite reduction at 570 °C, and wustite reduction above 570 °C (as it is unstable and will seek oxidation back to magnetite below that temperature). This article gives even lower temperatures, though it maintains wustite requires 570 °C or greater. The actual temps used by manufacturers may be higher than the chemically necessary temps, but that should be indicated separately. 2001:569:F82B:5B00:7468:1241:6076:AB25 (talk) 23:45, 15 April 2024 (UTC)Reply