Edge Rewrite
// HTMLRewriter · presentation

This page was redesigned at the edge.

Cloudflare fetched the original article and streamed it through HTMLRewriter to apply an entirely new visual system without rebuilding the source page.

Jump to content

Deep-dose equivalent

From Wikipedia, the free encyclopedia

The Deep-dose equivalent (DDE) is a measure of external radiation exposure defined by US regulations. It is reported alongside eye and shallow dose equivalents on typical US dosimetry reports. It represents the dose equivalent at a tissue depth of 1 cm (1000 mg/cm2) due to external whole-body exposure to ionizing radiation.[1]

Dose due to external radiation tends to decrease with depth because of the shielding effects of outer tissues. The reference depth of 1 cm essentially discounts alpha and beta radiation that are easily shielded by the skin, clothing, and bone surface, while taking minimal credit for any self-shielding from the more penetrating gamma rays. This makes the deep-dose equivalent a conservative measure of internal organ exposure to external radiation, while eye and skin exposure to external radiation must be accounted differently. Deep-dose equivalent does include any contribution from internal contamination.

See also

[edit]

References

[edit]
  1. 10 CFR 20.1003. US Nuclear Regulatory Commission. 2009.
[edit]
  • - "The confusing world of radiation dosimetry" - M.A. Boyd, 2009, U.S. Environmental Protection Agency. An account of chronological differences between USA and ICRP dosimetry systems.