Edge Rewrite
// HTMLRewriter · presentation

This page was redesigned at the edge.

Cloudflare fetched the original article and streamed it through HTMLRewriter to apply an entirely new visual system without rebuilding the source page.

// request.cf · coarse context

A page that knows where it met you.

Only coarse request metadata is shown. This demo does not display or persist visitor IP addresses.

Country
US
Cloudflare location
CMH
Connection
HTTP/2
Language
Not provided

Ray ID: a21e5cbefdd424ce

Jump to content

Talk:Sentinel lymph node

Page contents not supported in other languages.
Add topic
From Wikipedia, the free encyclopedia
Latest comment: 9 years ago by Rod57 in topic Rename or clarify

Some risk - so not 'harmless'

[edit]

This comment may or not be debateable, however, use of the word "harmless" in relation to a contrast agent is misleading for these reasons:

 All radioisotope injections [contrast agents] carry some risk to certain patients. 

Therefore, if the contrast agent is described as "harmless" then it infers that there are no risks involved to any patients. 2] One risk is that the patient may be allergic to the contrast agent. There may be other risks but will not be mentioned here. The the object of this edit is to avoid reliance on the word "harmless." Gammarama 22:06, 24 May 2007 (UTC)Reply

500µCi

[edit]

This should be expressed primarily in SI units = 20MBq (actually its really 18.5 but we round it.)Squid57squid (talk) 14:34, 29 May 2009 (UTC)Reply

Geiger Counter

[edit]

The device used is usually called a intra-operative gamma probe, it does not contain a Geiger tube which would be much too insensitive and would not provide energy discrimination and so be less directionally sensitive. The detector in an intra-operative gamma probe is usually a cadmium-zinc-telluride radiation sensitive diode, i.e. a solid state device that converts ionization directly into an electrical signal. Less commonly they have a detector comprising a scintillant crystal such as caesium iodide optically coupled to a photmultiplier tube. Squid57squid (talk) 14:34, 29 May 2009 (UTC)Reply

old science

[edit]

The disadvantages section notes that lymph node removal may not even be effective. Indeed, as it is believed metastases rarely come from node growths (Weinberg 2013, The Biology of Cancer). Perhaps more of this research should be highlighted. — Preceding unsigned comment added by 96.232.103.102 (talk) 00:02, 5 December 2013 (UTC)Reply

Rename or clarify

[edit]

This article seems to be about the sentinel node procedure rather than the nodes themselves. Since that redirects here I've mentioned it in the intro. - Rod57 (talk) 12:02, 5 November 2016 (UTC)Reply