Edge Rewrite
// HTMLRewriter · presentation

This page was redesigned at the edge.

Cloudflare fetched the original article and streamed it through HTMLRewriter to apply an entirely new visual system without rebuilding the source page.

// request.cf · coarse context

A page that knows where it met you.

Only coarse request metadata is shown. This demo does not display or persist visitor IP addresses.

Country
US
Cloudflare location
CMH
Connection
HTTP/2
Language
Not provided

Ray ID: a224e6eeb9a351a8

Jump to content

// Workers AI · dad joke modeWhy did pneumograph go to therapy? It had a lot of breathless issues.

From Wikipedia, the free encyclopedia
Pneumograph
Illustration
Synonymspneumatograph or spirograph
PurposeTo record velocity and force of chest movements in respiration

A pneumograph, also known as a pneumatograph or spirograph, is a device for recording velocity and force of chest movements during respiration. While spirometry measures respiratory rate and other markers of respiratory health via analysis of the airflow from the lungs during inhalation and exhalation, pneumography measures the respiratory rate via chest motion.

Principle of operation

[edit]

There are various kinds of pneumographic devices, which have different principles of operation.

Mechanical

[edit]

In one mechanism, a flexible rubber vessel is attached to the chest. The vessel is equipped with sensors such as accelerometers, piezoelectric sensors, or a fiber Bragg grating[1] to measure chest motion and obtain respiratory rate.

Electrical

[edit]

Other mechanisms are impedance based. In these methods, a high-frequency (tens to hundreds of kHz), low-amplitude current is injected across the chest cavity. The voltage resulting from this current injection is measured and the resistance is derived from the application of Ohm's law: . Current flows less easily through the chest as the lungs fill, so the resistance rises with increasing lung volume.[2]

References

[edit]
  1. Vitazkova, Diana; Foltan, Erik; Kosnacova, Helena; Micjan, Michal; Donoval, Martin; Kuzma, Anton; Kopani, Martin; Vavrinsky, Erik (6 February 2024). "Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies". Biosensors. 14 (2). MDPI Pub.: 90. doi:10.3390/bios14020090. PMC 10886711. PMID 38392009.
  2. Grenvik et al., (1973). "Impedance Pneumography: Comparison between Chest Impedance Changes and Respiratory Volumes in II Healthy Volunteers", Chest, 62:439-443.
  • Freundlich, Jerome J.; Erickson, James C. (1974). "Electrical Impedance Pneumography for Simple Nonrestrictive Continuous Monitoring of Respiratory Rate, Rhythm and Tidal Volume for Surgical Patients". Chest. 65 (2): 181–184. doi:10.1378/chest.65.2.181. PMID 4810676.
[edit]